    "cdp_num": null,
    "comment": "pillar - unused chimney above the roof of\r\nthe observatory main building directly\r\nconnected to the ground, excenter of\r\n217 EUREF point, taking part in programs:\r\nIGS EPOCH-92, EUREF-EAST, EUREF-POL,\r\nEUREF-BAL, GEODUC, EXTENDED SAGET, EUVN,\r\nHIRAC\/SolarMax\r\nPERMANENT GPS EUREF NETWORK\r\nFrom 1998 hourly data upload.",
    "conditions": [],
    "country": "Poland",
    "country_code_ISO": "POL",
    "date_from": "1996-06-08 00:00:00",
    "date_to": null,
    "description": "BRASS NAIL",
    "geological": {
        "bedrock": {
            "condition": "JOINTED",
            "type": "SEDIMENTARY"
        },
        "characteristic": "SAND and GRAVEL",
        "distance_to_fault": null,
        "fault_zone": "NO",
        "fracture_spacing": "1-10"
    },
    "iers_domes": "12207M002",
    "instrument_collocation": [
        {
            "comment": "P gravimeter Askania Gs-11\r\nProf.Bonatz\r\nP Blum horizontal pendulum",
            "date_from": "1997-05-08 00:00:00",
            "date_to": "1998-10-30 00:00:00",
            "status": "MOBILE",
            "type": "EARTH TIDAL GRAVIMETER"
        },
        {
            "comment": "",
            "date_from": "2008-10-01 00:00:00",
            "date_to": null,
            "status": "MOBILE",
            "type": "ABSOLUTE GRAVIMETER"
        },
        {
            "comment": "",
            "date_from": "2016-03-01 00:00:00",
            "date_to": null,
            "status": "PERMANENT",
            "type": "SUPERCONDUCTING GRAVIMETER"
        }
    ],
    "local_ties": [
        {
            "accuracy": 2,
            "comment": null,
            "cpd_num": null,
            "date_at": "1992-05-01 00:00:00",
            "dx": 76.35,
            "dy": 19.984,
            "dz": -72.511,
            "iers_domes": null,
            "name": "EUREF 217",
            "survey_method": "GPS CAMPAIGN",
            "usage": "LOCAL CONTROL"
        },
        {
            "accuracy": 5,
            "comment": "Old main point of Polish primary\r\ngeodetic network.",
            "cpd_num": null,
            "date_at": "1992-05-04 00:00:00",
            "dx": 79.827,
            "dy": -55.13,
            "dz": -56.175,
            "iers_domes": null,
            "name": "BG00",
            "survey_method": "GPS CAMPAIGN",
            "usage": "LOCAL CONTROL"
        },
        {
            "accuracy": 2,
            "comment": "Old AFU satellite photographic camera dome",
            "cpd_num": null,
            "date_at": "1999-02-03 00:00:00",
            "dx": 86.51,
            "dy": 14.354,
            "dz": -77.571,
            "iers_domes": null,
            "name": "BG03",
            "survey_method": "GPS CAMPAIGN",
            "usage": "LOCAL CONTROL"
        },
        {
            "accuracy": 1,
            "comment": null,
            "cpd_num": null,
            "date_at": "2001-04-01 00:00:00",
            "dx": 76.3504,
            "dy": 19.9838,
            "dz": -72.5116,
            "iers_domes": null,
            "name": "EUREF 217 = BOGI in EUVN",
            "survey_method": "GPS CAMPAIGN",
            "usage": "LOCAL CONTROL"
        },
        {
            "accuracy": 1,
            "comment": "hourly and daily data upload",
            "cpd_num": null,
            "date_at": "2001-10-01 00:00:00",
            "dx": 76.351,
            "dy": 19.9838,
            "dz": -72.5114,
            "iers_domes": "12207M003",
            "name": "EUREF 217 = BOGI in IGLOS",
            "survey_method": "GPS CAMPAIGN",
            "usage": "IGS\/IGLOS PERMANENT STATION"
        }
    ],
    "location": {
        "city": "Borowa Gora",
        "coordinates": {
            "X": 3633739.3,
            "Y": 1397433.9,
            "Z": 5035353.3,
            "altitude": 149.6,
            "lat": 52.47594516831576,
            "lon": 21.035338836057207
        },
        "country": "Poland",
        "country_iso_code": "POL",
        "description": "40 km to the North of Warsaw.\r\nPrecambrian platform of the Eurasian plate.",
        "state": null,
        "tectonic": {
            "plate_name": "EURASIAN"
        }
    },
    "logs": {
        "contact": "IGIK GNSS team (gnss@igik.edu.pl)",
        "date": "2025-03-17 00:00:00",
        "log_type": "UPDATE",
        "modified": "UNAVAILABLE",
        "previous": "UNAVAILABLE",
        "title": "BOGO00POL.xml"
    },
    "marker": "BOGO",
    "monument": {
        "description": "PILLAR",
        "foundation": "CONCRETE BLOCK",
        "foundation_depth": 2.5,
        "height": 11.5,
        "monument_inscription": "BG01 on the brass plate close to the point"
    },
    "monument_num": 0,
    "name": "Borowa Gora",
    "receiver_num": 0,
    "station_contacts": [
        {
            "contact": {
                "agency": {
                    "abbreviation": "IGIK",
                    "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                    "infos": "",
                    "name": "Institute of Geodesy and Cartography",
                    "www": ""
                },
                "comment": "",
                "email": "gnss@igik.edu.pl",
                "name": "IGIK GNSS team",
                "phone": "",
                "role": "site_owner",
                "title": ""
            }
        },
        {
            "contact": {
                "agency": {
                    "abbreviation": "IGIK",
                    "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                    "infos": "",
                    "name": "Institute of Geodesy and Cartography",
                    "www": ""
                },
                "comment": "",
                "email": "gnss@igik.edu.pl",
                "name": "IGIK GNSS team",
                "phone": "",
                "role": "metadata_custodian",
                "title": ""
            }
        }
    ],
    "station_items": [
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1996-06-08 00:00:00",
                "date_to": "1996-12-05 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "1E82"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": 15,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1996-12-05 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1996-12-06 00:00:00",
                "date_to": "1999-01-22 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "1E97"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 15,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "1996-12-06 00:00:00",
                        "date_to": "1999-01-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-01-22 00:00:00",
                "date_to": "1999-07-16 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "1F50"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": 15,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "1999-01-22 00:00:00",
                        "date_to": "1999-07-16 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-07-16 00:00:00",
                "date_to": "1999-12-03 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "CC00"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "1999-07-16 00:00:00",
                        "date_to": "1999-12-03 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-12-03 00:00:00",
                "date_to": "2004-07-22 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "700570E05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "CC00"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "1999-12-03 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2004-07-22 00:00:00",
                "date_to": "2006-03-31 13:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "700724B01833"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "1K00"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2004-07-22 00:00:00",
                        "date_to": "2006-03-31 13:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2006-03-31 13:00:00",
                "date_to": "2007-01-11 08:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASHTECH Z-XII3"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "700570E05139"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "CD00"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2006-03-31 13:00:00",
                        "date_to": "2007-01-11 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2007-01-11 22:00:00",
                "date_to": "2008-01-28 20:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "TPS EUROCARD"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "MT312310851"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "2.3 MAY,13,2003 P1"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2007-01-11 22:00:00",
                        "date_to": "2008-01-28 20:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2008-01-28 20:00:00",
                "date_to": "2016-02-16 18:40:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "TPS EUROCARD"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "MT312310851"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "2.6.1 Jan,10,2008"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2008-01-28 20:00:00",
                        "date_to": "2016-02-16 18:40:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NaN"
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2016-02-16 18:45:00",
                "date_to": "2018-01-23 16:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "TPS EUROCARD"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "MT312310851"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "2.6.1 Jan,10,2008"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2016-02-16 18:45:00",
                        "date_to": "2018-01-23 16:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-01-23 16:16:00",
                "date_to": "2025-03-17 08:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JPS EGGDT"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LGGD_0242"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "2.7.0 Mar,31,2008"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2018-01-23 16:16:00",
                        "date_to": "2025-03-17 08:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2025-03-17 10:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3T DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "OEM_06652"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.6.14 Nov,19,2018"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2025-03-17 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "1) Antenna removed because of heavy storm\r\n2) From 08-JUN-1996 to 17-JUL-2001\r\nan incorrect antenna number (11657)\r\nhas been used for this antenna.",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1996-06-08 00:00:00",
                "date_to": "2001-07-17 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "antenna_type"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASH700936C_M"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "11957"
                    },
                    {
                        "attribute": {
                            "name": "antenna_reference_point"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "BPA"
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_up_ecc"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_north_ecc"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_east_ecc"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "alignment_from_true_n"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_type"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_length"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": 30,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "antenna"
                }
            }
        },
        {
            "item": {
                "comment": "1) Antenna removed because of heavy storm\r\n2) From 08-JUN-1996 to 17-JUL-2001\r\nan incorrect antenna number (11657)\r\nhas been used for this antenna.",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1996-06-08 00:00:00",
                "date_to": "2001-07-17 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "radome_type"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "SNOW"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "2001-07-17 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "radome"
                }
            }
        },
        {
            "item": {
                "comment": "Antenna in 4.1 reinstalled at\r\nthe former position",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2001-08-17 13:30:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "antenna_type"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "ASH700936C_M"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "11957"
                    },
                    {
                        "attribute": {
                            "name": "antenna_reference_point"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "BPA"
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_up_ecc"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_north_ecc"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_east_ecc"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "alignment_from_true_n"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_type"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_length"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 30,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "antenna"
                }
            }
        },
        {
            "item": {
                "comment": "Antenna in 4.1 reinstalled at\r\nthe former position",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2001-08-17 13:30:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "radome_type"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "SNOW"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2001-08-17 13:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "radome"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1996-06-08 00:00:00",
                "date_to": "1998-01-01 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "standard_type"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1998-01-01 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "EXTERNAL QUARTZ"
                    },
                    {
                        "attribute": {
                            "name": "input_frequency"
                        },
                        "date_from": "1996-06-08 00:00:00",
                        "date_to": "1998-01-01 00:00:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "frequency_standard"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1998-01-01 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "standard_type"
                        },
                        "date_from": "1998-01-01 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "EXTERNAL RUBIDIUM"
                    },
                    {
                        "attribute": {
                            "name": "input_frequency"
                        },
                        "date_from": "1998-01-01 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "frequency_standard"
                }
            }
        },
        {
            "item": {
                "comment": "placed in the meteorological box",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-05-17 00:00:00",
                "date_to": "2004-07-22 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-710HB"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 600,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 0.8,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 7,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": "1999-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "humidity_sensor"
                }
            }
        },
        {
            "item": {
                "comment": "placed in the meteorological box",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2005-04-15 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-710HB"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.8,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 7,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": "2005-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "humidity_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-05-17 00:00:00",
                "date_to": "2004-07-22 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-716"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 600,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 0.5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 8,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": "1999-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "pressure_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2005-04-15 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-716"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 8,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": "2005-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "pressure_sensor"
                }
            }
        },
        {
            "item": {
                "comment": "placed in the meteorological box",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "1999-05-17 00:00:00",
                "date_to": "2004-07-22 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-710HB"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 600,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 0.15,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "UNASPIRATED"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": null,
                        "value_numeric": 7,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "1999-05-17 00:00:00",
                        "date_to": "2004-07-22 00:00:00",
                        "value_date": "1999-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "temperature_sensor"
                }
            }
        },
        {
            "item": {
                "comment": "placed in the meteorological box",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "IGIK",
                        "address": "Modzelewskiego 27\n02-679 Warszawa\nPoland",
                        "infos": "",
                        "name": "Institute of Geodesy and Cartography",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@igik.edu.pl",
                    "name": "IGIK GNSS team",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2005-04-15 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LB-710HB"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "LAB-EL"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.15,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "UNASPIRATED"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 7,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2005-04-15 00:00:00",
                        "date_to": null,
                        "value_date": "2005-04-01 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "temperature_sensor"
                }
            }
        }
    ],
    "station_networks": [
        {
            "name": "EPN"
        },
        {
            "name": "EPOS"
        }
    ],
    "station_type": "GNSS Continuous"
}