{
    "cdp_num": null,
    "comment": null,
    "conditions": [],
    "country": "Germany",
    "country_code_ISO": "DEU",
    "date_from": "2018-09-29 00:00:00",
    "date_to": null,
    "description": null,
    "geological": {
        "bedrock": {
            "condition": null,
            "type": null
        },
        "characteristic": null,
        "distance_to_fault": null,
        "fault_zone": null,
        "fracture_spacing": null
    },
    "iers_domes": "10919M001",
    "instrument_collocation": [],
    "local_ties": [],
    "location": {
        "city": "Garmisch Partenkirchen",
        "coordinates": {
            "X": 4246132.08,
            "Y": 824180.761,
            "Z": 4675742.816,
            "altitude": 2988,
            "lat": 47.4207768930592,
            "lon": 10.984608234499634
        },
        "country": "Germany",
        "country_iso_code": "DEU",
        "description": "",
        "state": "Bavaria",
        "tectonic": {
            "plate_name": "EURASIAN"
        }
    },
    "logs": {
        "contact": "Markus Bradke",
        "date": "2025-02-06 00:00:00",
        "log_type": "UPDATE",
        "modified": "UNAVAILABLE",
        "previous": "UNAVAILABLE",
        "title": "ZUGG00DEU.xml"
    },
    "marker": "ZUGG",
    "monument": {
        "description": "PILLAR",
        "foundation": "STEEL ROD",
        "foundation_depth": null,
        "height": 1.2,
        "monument_inscription": null
    },
    "monument_num": 0,
    "name": "Zugspitze",
    "receiver_num": 0,
    "station_contacts": [
        {
            "contact": {
                "agency": {
                    "abbreviation": "GFZ",
                    "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                    "infos": "",
                    "name": "GFZ Helmholtz Centre for Geosciences",
                    "www": ""
                },
                "comment": "",
                "email": "gnss@gfz-potsdam.de",
                "name": "GFZ Network Operator",
                "phone": "",
                "role": "site_owner",
                "title": ""
            }
        },
        {
            "contact": {
                "agency": {
                    "abbreviation": "GFZ",
                    "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                    "infos": "",
                    "name": "GFZ Helmholtz Centre for Geosciences",
                    "www": ""
                },
                "comment": "",
                "email": "bradke@gfz-potsdam.de",
                "name": "Markus Bradke",
                "phone": "+49 331 2881182",
                "role": "metadata_custodian",
                "title": ""
            }
        }
    ],
    "station_items": [
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5\r\nData not trustworthy from\r\n29-JUN-2019 to 04-SEP-2019",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 23:59:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.7.3P1"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5\r\nHarddisk replaced due to short circuit",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 07:30:00",
                "date_to": "2019-09-16 09:59:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL+BDS+SBAS"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.7.6"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": "2019-09-16 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5\r\nRemoved BDS L1 tracking",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-16 10:00:00",
                "date_to": "2020-03-26 10:24:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.7.6"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2019-09-16 10:00:00",
                        "date_to": "2020-03-26 10:24:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5\r\nActivation of independent tracking",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2020-03-26 10:25:00",
                "date_to": "2020-11-11 13:49:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.7.9"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2020-03-26 10:25:00",
                        "date_to": "2020-11-11 13:49:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2020-11-11 13:50:00",
                "date_to": "2021-06-24 08:17:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3.7.10"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2020-11-11 13:50:00",
                        "date_to": "2021-06-24 08:17:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5\r\ndeactivated clock steering",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2021-06-24 08:18:00",
                "date_to": "2023-01-19 09:59:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "4.1.01-210527"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2021-06-24 08:18:00",
                        "date_to": "2023-01-19 09:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": "Board revision TRE_G3TH_5",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2023-01-19 10:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "receiver_type"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAVAD TRE_G3TH DELTA"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "213"
                    },
                    {
                        "attribute": {
                            "name": "satellite_system"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "GPS+GLO+GAL"
                    },
                    {
                        "attribute": {
                            "name": "firmware_version"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "4.2.01-220630"
                    },
                    {
                        "attribute": {
                            "name": "elevation_cutoff_setting"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "temperature_stabilization"
                        },
                        "date_from": "2023-01-19 10:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "receiver"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 23:59:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "antenna_type"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAV_GRANT-G3T"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "3479"
                    },
                    {
                        "attribute": {
                            "name": "antenna_reference_point"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "BAM"
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_up_ecc"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 0.13,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_north_ecc"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_east_ecc"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "alignment_from_true_n"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_type"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "EcoFlex 10"
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_length"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": 30,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "antenna"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 23:59:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "radome_type"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NONE"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 23:59:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "radome"
                }
            }
        },
        {
            "item": {
                "comment": "Antenna replaced due to short circuit",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 07:30:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "antenna_type"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "JAV_GRANT-G3T"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "1859"
                    },
                    {
                        "attribute": {
                            "name": "antenna_reference_point"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "BAM"
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_up_ecc"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.13,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_north_ecc"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "marker_arp_east_ecc"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "alignment_from_true_n"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_type"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "EcoFlex 10"
                    },
                    {
                        "attribute": {
                            "name": "antenna_cable_length"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 30,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "antenna"
                }
            }
        },
        {
            "item": {
                "comment": "Antenna replaced due to short circuit",
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 07:30:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "radome_type"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NONE"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 07:30:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "radome"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT520"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "G4540049"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": "2011-12-03 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "humidity_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT536"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "R1520245"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": "2019-06-04 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "humidity_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT520"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "G4540049"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 0.5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": "2011-12-03 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "pressure_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT536"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "R1520245"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.5,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": "2019-06-04 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "pressure_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2018-09-29 00:00:00",
                "date_to": "2019-07-11 00:00:00",
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT520"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "G4540049"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": 0.3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2018-09-29 00:00:00",
                        "date_to": "2019-07-11 00:00:00",
                        "value_date": "2011-12-03 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "temperature_sensor"
                }
            }
        },
        {
            "item": {
                "comment": null,
                "contact_as_owner": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "bradke@gfz-potsdam.de",
                    "name": "Markus Bradke",
                    "phone": "+49 331 2881182",
                    "role": "site_owner",
                    "title": ""
                },
                "contact_as_producer": {
                    "agency": {
                        "abbreviation": "GFZ",
                        "address": "Telegrafenberg A17\nD-14473 Potsdam\nGermany",
                        "infos": "",
                        "name": "GFZ Helmholtz Centre for Geosciences",
                        "www": ""
                    },
                    "comment": "",
                    "email": "gnss@gfz-potsdam.de",
                    "name": "GFZ Network Operator",
                    "phone": "",
                    "role": "metadata_custodian",
                    "title": ""
                },
                "date_from": "2019-09-04 00:00:00",
                "date_to": null,
                "item_attributes": [
                    {
                        "attribute": {
                            "name": "sensor_model"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "WXT536"
                    },
                    {
                        "attribute": {
                            "name": "manufacturer"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "Vaisala"
                    },
                    {
                        "attribute": {
                            "name": "serial_number"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "R1520245"
                    },
                    {
                        "attribute": {
                            "name": "data_sampling_interval"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 300,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "accuracy"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": 0.3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "aspiration"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": null,
                        "value_varchar": "NATURAL"
                    },
                    {
                        "attribute": {
                            "name": "height_diff_to_ant"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": null,
                        "value_numeric": -3,
                        "value_varchar": null
                    },
                    {
                        "attribute": {
                            "name": "calibration_date"
                        },
                        "date_from": "2019-09-04 00:00:00",
                        "date_to": null,
                        "value_date": "2019-06-04 00:00:00",
                        "value_numeric": null,
                        "value_varchar": null
                    }
                ],
                "item_type": {
                    "name": "temperature_sensor"
                }
            }
        }
    ],
    "station_networks": [
        {
            "name": "EPOS"
        },
        {
            "name": "GFZ"
        }
    ],
    "station_type": "GNSS Continuous"
}