     EOST00FRA Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : EOST GNSS team (renag-eost@eost.unistra.fr)
     Date Prepared            : 2025-07-25
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : eost00fra_20240829.log
      Modified/Added Sections : 12


1.   Site Identification of the GNSS Monument

     Site Name                : EOST
     Nine Character ID        : EOST00FRA
     Monument Inscription     : none
     IERS DOMES Number        : 10014M003
     CDP Number               : none
     Monument Description     : STEEL MAST
       Height of the Monument : 1.5 m
       Monument Foundation    : ROOF
       Foundation Depth       : (m)
     Marker Description       : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc)
     Date Installed           : 2007-04-12
     Geologic Characteristic  : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc)
       Bedrock Type           : (IGNEOUS/METAMORPHIC/SEDIMENTARY)
       Bedrock Condition      : (FRESH/JOINTED/WEATHERED)
       Fracture Spacing       : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
       Fault zones nearby     : (YES/NO/Name of the zone)
         Distance/activity    : (multiple lines)
     Additional Information   : The antenna is fixed on a 1.5 meter high mast
                              : located on top of the Institute building
                              : (a 5-floor building)


2.   Site Location Information

     City or Town             : Strasbourg
     State or Province        : Bas-Rhin
     Country or Region        : FRA
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 4188985.181
       Y coordinate (m)       : 571026.510
       Z coordinate (m)       : 4759936.197
       Latitude (N is +)      : +483447.44
       Longitude (E is +)     : +0074544.99
       Elevation (m,ellips.)  : 213.3
     Additional Information   : (multiple lines)


3.   GNSS Receiver Information

3.1  Receiver Type            : TRIMBLE NETRS
     Satellite System         : GPS
     Serial Number            : 4616261992
     Firmware Version         : 1.1-3
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2007-04-12
     Date Removed             : 2015-08-07T08:54Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.2  Receiver Type            : TRIMBLE NETRS
     Satellite System         : GPS
     Serial Number            : 4616261992
     Firmware Version         : 1.3-2
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2015-08-07T08:58Z
     Date Removed             : 2020-01-13T14:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.3  Receiver Type            : TRIMBLE NETR9
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 5615R50076
     Firmware Version         : 5.03
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-01-13T14:00Z
     Date Removed             : 2021-09-29T08:55Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.4  Receiver Type            : TRIMBLE NETR9
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 5615R50076
     Firmware Version         : 5.37
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2021-09-29T08:55Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TRM41249.00     NONE
     Serial Number            : 60142219
     Antenna Reference Point  : BAM
     Marker->ARP Up Ecc. (m)  :   0.0000
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 30 m
     Date Installed           : 2007-04-12
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : (multiple lines)

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2007-04-12/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -12 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2007-04-12/2007-08-31
       Notes                  : The sensor is on the 3rd floor, but inside the
                              : building.  The exact day was unfortunately not
                              : reported but should be in August or September,
                              : 2007 (put at 08-31 for avoiding errors).

8.1.2  Humidity Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -12 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2007-08-31/2010-01-09
       Notes                  : The sensor is on the 3rd floor,
                              : but outside the building along the wall

8.1.3  Humidity Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -3 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2010-01-09/2010-11-10
       Notes                  : The sensor is on the 5rd floor,
                              : but outside the building along the wall

8.1.4  Humidity Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : 1.1 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2010-11-10/CCYY-MM-DD
       Notes                  : The sensor is on a mast on the roof.
                              : The sensor is above the GPS antenna.

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :  60 sec
       Accuracy               : (hPa)
       Height Diff to Ant     : -12 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2007-04-12/2010-01-08
       Notes                  : The sensor is on the 3rd floor.

8.2.2  Pressure Sensor Model  : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval :  60 sec
       Accuracy               : (hPa)
       Height Diff to Ant     : -5 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2010-01-08/CCYY-MM-DD
       Notes                  : The sensor is on the 5th floor.

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval : 60 sec
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -12 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2007-04-12/2007-08-31
       Notes                  : The sensor is inside the building (3rd floor),
                              : not outside.  The temperature is the temperature
                              : of the room !

8.3.2  Temp. Sensor Model     : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval : 60 sec
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -12 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2007-08-31/2010-01-09
       Notes                  : The sensor is on the 3rd floor, outside the
                              : building, along the wall. The exact day was
                              : unfortunately not reported but should
                              : be in August or September, 2007.
                              : (put at 08-31 for avoiding errors).

8.3.3  Temp. Sensor Model     : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval : 60 sec
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : -3 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2010-01-09/2010-11-10
       Notes                  : The sensor is on the 5rd floor, outside the
                              : building, along the wall.

8.3.4  Temp. Sensor Model     : PTU300
       Manufacturer           : VAISALA
       Serial Number          : 
       Data Sampling Interval : 60 sec
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : 1.1 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2010-11-10/CCYY-MM-DD
       Notes                  : From Nov. 10th, 2010 (14h30 local time), the
                              : sensor is on a mast on the roof of the EOST
                              : building (2.25 m height from the roof). The
                              : sensor is above the GPS antenna at an horizontal
                              : distance of 1.77 m.

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Ecole et Observatoire des Sciences de la Terre
     Preferred Abbreviation   : EOST
     Mailing Address          : rue René Descartes 5
                              : F-67084 Strasbourg Cedex
                              : France
     Primary Contact
       Contact Name           : EOST GNSS team
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : renag-eost@eost.unistra.fr
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


12.  Responsible Agency (if different from 11.)

     Agency                   : Epos-France
                              : RENAG
                              : CNRS
     Preferred Abbreviation   : Epos-Fr
     Mailing Address          : rue Michel-Ange 3
                              : 75796 Paris Cedex 16
                              : France
     Primary Contact
       Contact Name           : RENAG GNSS direction and data center
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : renag-ops@groupes.renater.fr
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : RENAGi (ftp://renag.unice.fr)
     Secondary Data Center    : IGN ftp://rgpdata.ign.fr or rgpdata.ensg.ign.fr
     URL for More Information : http;//webrenag.unice.fr
     Hardcopy on File
       Site Map               : (Y or URL)
       Site Diagram           : (Y or URL)
       Horizon Mask           : (Y or URL)
       Monument Description   : (Y or URL)
       Site Pictures          : (Y or URL)
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

TRM41249.00

    / ----------------------+--------------------- \   
   +                        +                       +  
    \ -------------------------------------------- /   
                    \               /
                     \             /
                      \-----+-----/                    <--  0.0000  ARP=BAM

   <--                   0.3396                  -->
