     LYSH00CZE Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : GOP operation center (gop_oc@pecny.cz)
     Date Prepared            : 2024-08-27
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : lysh00cze_20221123.log
      Modified/Added Sections : 12


1.   Site Identification of the GNSS Monument

     Site Name                : LYSA HORA
     Nine Character ID        : LYSH00CZE
     Monument Inscription     : 
     IERS DOMES Number        : 11522M001
     CDP Number               : none
     Monument Description     : STEEL SCREW IN THE STEEL ROD ON THE CHIMNEY
       Height of the Monument : 2.2 m
       Monument Foundation    : BUILDING ON THE ROCK
       Foundation Depth       : 1.7 m
     Marker Description       : INTERSECTION OF AXIS OF SCREW WITH TOP OF ROD
     Date Installed           : 2004-12-02T13:45Z
     Geologic Characteristic  : BEDROCK
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : JOINTED
       Fracture Spacing       : 0 cm
       Fault zones nearby     : NO
         Distance/activity    : (multiple lines)
     Additional Information   : Foundation Depth is underground part of
                              : building. Height of building (between ground
                              : level and roof) is 7.3 m. Point is 9.5 m
                              : above ground.


2.   Site Location Information

     City or Town             : LYSA HORA/OSTRAVICE
     State or Province        : MORAVIA
     Country or Region        : CZE
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 3934178.480
       Y coordinate (m)       : 1312357.128
       Z coordinate (m)       : 4831237.829
       Latitude (N is +)      : +493246.28
       Longitude (E is +)     : +0182651.31
       Elevation (m,ellips.)  : 1374.9
     Additional Information   : ETRS89 coordinates from CEGRN03 and
                              : excentricity determination


3.   GNSS Receiver Information

3.1  Receiver Type            : TPS GB-1000
     Satellite System         : GPS+GLO
     Serial Number            : 20292
     Firmware Version         : 2.3p4
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2005-06-22T16:20Z
     Date Removed             : 2017-03-05T12:00Z
     Temperature Stabiliz.    : none
     Additional Information   : full serial number is 220292

3.2  Receiver Type            : TPS NETG3
     Satellite System         : GPS+GLO
     Serial Number            : 01166
     Firmware Version         : 3.4 p2
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2017-03-05T13:30Z
     Date Removed             : 2019-04-03T15:50Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 401-01166

3.3  Receiver Type            : TPS NETG3
     Satellite System         : GPS+GLO
     Serial Number            : 01166
     Firmware Version         : 4.0 p7
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2019-04-03T15:50Z
     Date Removed             : 2019-11-16T10:15Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 401-01166

3.4  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 10702
     Firmware Version         : 5.2.2 Dec,06,2018
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2019-11-16T10:20Z
     Date Removed             : 2020-04-16T08:04Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-10702

3.5  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 10702
     Firmware Version         : 5.2.4 Feb,13,2020
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2020-04-16T08:20Z
     Date Removed             : 2021-05-27T16:20Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-10702

3.6  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 10702
     Firmware Version         : 5.2.7 Sep,09,2020
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2021-05-27T16:40Z
     Date Removed             : 2021-08-09T09:15Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-10702

3.7  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 10702
     Firmware Version         : 5.4+2105281211
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2021-08-09T10:25Z
     Date Removed             : 2022-11-22T18:08Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-10702

3.8  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 10702
     Firmware Version         : 5.5+2207150000
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2022-11-22T18:20Z
     Date Removed             : 2024-06-03T19:00Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-10702

3.9  Receiver Type            : TPS NET-G5
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 13004
     Firmware Version         : 5.5.2+2306270006
     Elevation Cutoff Setting : 3 deg
     Date Installed           : 2024-06-05T11:00Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : full serial number is 1294-13004

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TPSCR3_GGD      CONE
     Serial Number            : 70442
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1727
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : CONE
     Radome Serial Number     : none
     Antenna Cable Type       : GES ELECTRONICS RG213/U + TOPCON cable
     Antenna Cable Length     : 24 m
     Date Installed           : 2005-06-22T16:20Z
     Date Removed             : 2008-09-29T08:30Z
     Additional Information   : full serial number is 2170442

4.2  Antenna Type             : TPSCR.G3        TPSH
     Serial Number            : 30594
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1727
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : TPSH
     Radome Serial Number     : none
     Antenna Cable Type       : GES ELECTRONICS RG213/U + TOPCON cable
     Antenna Cable Length     : 24 m
     Date Installed           : 2009-05-08
     Date Removed             : 2019-10-04T09:30Z
     Additional Information   : full serial number is 383-0594

4.3  Antenna Type             : TPSCR.G5        TPSH
     Serial Number            : 13199
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1727
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : TPSH
     Radome Serial Number     : none
     Antenna Cable Type       : GES ELECTRONICS RG213/U + TOPCON cable
     Antenna Cable Length     : 24 m
     Date Installed           : 2019-10-04T11:45Z
     Date Removed             : 2021-05-27T08:30Z
     Additional Information   : full serial number is 762-13199

4.4  Antenna Type             : TPSCR.G5C       TPSH
     Serial Number            : 1364-10163
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1727
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : TPSH
     Radome Serial Number     : none
     Antenna Cable Type       : GES ELECTRONIC
     Antenna Cable Length     : 30 m
     Date Installed           : 2021-05-27T11:43Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : full serial number is 1364-10163

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.1  Tied Marker Name         : GEODYNAMIC PILLAR/TRIANGULATION STATION
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : none
     Tied Marker DOMES Number : 11522M002
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : 21.953 m
       dy (m)                 : -16.661 m
       dz (m)                 : -17.429 m
     Accuracy (mm)            : 1 mm
     Survey method            : GPS CAMPAIGN
     Date Measured            : 2005-06-23
     Additional Information   : (dx = X of 11522M002 - X of 11522M001 ...)

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2005-06-22/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.1  Instrumentation Type     : METEOROLOGICAL STATION
       Status                 : PERMANENT
       Effective Dates        : 2005-06-22/CCYY-MM-DD
       Notes                  : (multiple lines)

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : TH99
       Manufacturer           : ANEMO, CZ
       Serial Number          : TH904400
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : 3 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2004-12-04
       Effective Dates        : 2005-06-22/2008-09-29
       Notes                  : the sensor is 0.15 m below monument marker
                              : (reference point LYSH 11522M001)
                              : sensor was compared with the similar sensor
                              : on the GOPE station

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : TMAG 518 N4F
       Manufacturer           : CRESSTO, CZ
       Serial Number          : 1998/04
       Data Sampling Interval :  60 sec
       Accuracy               : 0.2 hPa
       Height Diff to Ant     : -0.12 m
       Calibration date       : 2004-12-04
       Effective Dates        : 2005-06-22/2008-09-29
       Notes                  : the sensor is 0.12 m below monument marker
                              : (reference point LYSH 11522M001)
                              : sensor was compared with the similar sensor
                              : on the GOPE station

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : TH99
       Manufacturer           : ANEMO, CZ
       Serial Number          : TH904400
       Data Sampling Interval : 60 sec
       Accuracy               : 0.3 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2004-12-04
       Effective Dates        : 2005-06-22/2008-09-29
       Notes                  : the sensor is 0.15 m below monument marker
                              : (reference point LYSH 11522M001)
                              : sensor was compared with the similar sensor
                              : on the GOPE station

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.1  Signal Obstructions    : TV BROADCASTING ANTENNA
       Effective Dates        : 2005-06-22/CCYY-MM-DD
       Additional Information : north-east direction

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : VSB - Technical University Ostrava
     Preferred Abbreviation   : VSB - TUO
     Mailing Address          : Vysoka skola banska-Technicka univerzita Ostrava
                              : 15 / 70833
                              : 17. listopadu 15 Institut geoinformatiky
                              : Czechia
     Primary Contact
       Contact Name           : K548 department
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : kat548@vsb.cz
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


12.  Responsible Agency (if different from 11.)

     Agency                   : Research Institute of Geodesy, Topography and
                              : Cartography
                              : Geodetic Observatory Pecny
     Preferred Abbreviation   : RIGTC GOP
     Mailing Address          : Pecny 244
                              : CZ-25165 Ondrejov
                              : Czechia
     Primary Contact
       Contact Name           : GOP operation center
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : gop_oc@pecny.cz
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : station is hosted by:
                              : Agency :            Czech Hydrometeorological
                              : Institute
                              : Preferred Abbrev. : CHMU
                              : Mailing Address :   Meteorologicka stanice Lysa
                              : hora
                              : CZ-739 11 posta Frydlant nad Ostravici


13.  More Information

     Primary Data Center      : TopNet network center
     Secondary Data Center    : VESOG operational center
     URL for More Information : http://www.pecny.cz/vesog/stanice/lysh.html
     Hardcopy on File
       Site Map               : on the web page
       Site Diagram           : on the web page
       Horizon Mask           : on the web page
       Monument Description   : on the web page
       Site Pictures          : on the web page
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

TPSCR3_GGD  CONE


                           /  \
                         /      \
                        /        \
                      /            \
                     /              \
                   /                  \
                  /                    \
                /                        \
               /                          \
             /                              \
            /                                \
          /                                    \
         /                                      \
       /                                          \
      /                 ---------                  \
    /                 /     +     \                  \     <--  0.104 L2
   /                 |      +      |                  \    <--  0.081 L1
  |+--------------------------------------------------+|   <--  0.071 TCR
  ||                                                  ||
   |                                                  |
   |                                                  |
   |                                                  |
   +-----------------+-------------+------------------+    <--  0.003 BCR
                      +-----x-----+                        <--  0.000 BPA=ARP

   <--                    0.326                     -->





Heights above monument marker


                           /  \
                         /      \
                        /        \
                      /            \
                     /              \
                   /                  \
                  /                    \
                /                        \
               /                          \
             /                              \
            /                                \
          /                                    \
         /                                      \
       /                                          \
      /                 ---------                  \
    /                 /     +     \                  \     <--  0.277  L2
   /                 |      +      |                  \    <--  0.254  L1
  |+--------------------------------------------------+|   <--  0.244  TCR
  ||                                                  ||
   |                                                  |
   |                                                  |
   |                                                  |
   +-----------------+-------------+------------------+    <--  0.176  BCR
                      +-----x-----+                        <--  0.1727 ARP
                          |   |
                          |   |
                          |   |
                          |   |
                          |   |
                          |   |
                          |   |
                       +--+---+--+
                       |         |
                       |         |
                       |         |
                       ++---X---++                         <--  0.0000
                        |       |
                        | STEEL |
                        |       |
                        |  ROD  |
                        |       |