OBE200DEU Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Markus Bradke Date Prepared : 2021-10-28 Report Type : UPDATE If Update: Previous Site Log : obe200deu_20211026.log Modified/Added Sections : 11 1. Site Identification of the GNSS Monument Site Name : Oberpfaffenhofen Four Character ID : OBE2 Monument Inscription : IERS DOMES Number : 14208M003 CDP Number : (A4) Monument Description : STEEL MAST Height of the Monument : 2.00 m Monument Foundation : ROOF Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 2001-07-28T00:00Z Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : The pillar got lost due to construction work. : OBE2 is closed and replaced by the nearby : station OBE3. 2. Site Location Information City or Town : Oberpfaffenhofen State or Province : Bavaria Country : Germany Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4186575.000 Y coordinate (m) : 835012.000 Z coordinate (m) : 4723760.000 Latitude (N is +) : +480509.90 Longitude (E is +) : +0111646.64 Elevation (m,ellips.) : 650.7 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : AOA SNR-8000 ACT Satellite System : GPS Serial Number : 231-U Firmware Version : 3.3.32.3 Elevation Cutoff Setting : 0 deg Date Installed : 2001-07-28T00:00Z Date Removed : 2003-04-11T10:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.2 Receiver Type : AOA BENCHMARK ACT Satellite System : GPS Serial Number : 1107 Firmware Version : 3.3.32.2N Elevation Cutoff Setting : 0 deg Date Installed : 2003-04-11T12:00Z Date Removed : 2008-02-12T00:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 236 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0460 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2001-07-28T00:00Z Date Removed : 2008-02-12T00:00Z Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : PRARE Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : Survey method : TRIANGULATION Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 5 MHz Effective Dates : 1994-01-31/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : PRARE Status : PERMANENT Effective Dates : 1994-01-31/CCYY-MM-DD Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HC 500 Manufacturer : TimeTech/Gresinger Serial Number : Data Sampling Interval : 600 sec Accuracy (% rel h) : 1 % rel h Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : 0 m Calibration date : (CCYY-MM-DD) Effective Dates : 1996-10-11/CCYY-MM-DD Notes : The sensor is part of the meteorological 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTB100B Manufacturer : Vaisala Serial Number : Data Sampling Interval : 600 sec Accuracy : 0.5 hPa Height Diff to Ant : 0 m Calibration date : (CCYY-MM-DD) Effective Dates : 1996-10-11/CCYY-MM-DD Notes : The sensor is part of the meteorological 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PT100 Manufacturer : TimeTech Serial Number : Data Sampling Interval : 600 sec Accuracy : 0.25 deg C Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : 0 m Calibration date : (CCYY-MM-DD) Effective Dates : 1996-10-11/CCYY-MM-DD Notes : The sensor is part of the meteorological 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Helmholtz Centre Potsdam : GFZ German Research Centre for Geosciences : Geodesy Preferred Abbreviation : GFZ Mailing Address : Telegrafenberg A17 : D-14473 Potsdam : Germany Primary Contact Contact Name : GFZ Network Operator Telephone (primary) : Telephone (secondary) : Fax : E-mail : gnss@gfz-potsdam.de Secondary Contact Contact Name : Markus Bradke Telephone (primary) : +49 331 2881182 Telephone (secondary) : Fax : +49 331 2881759 E-mail : bradke@gfz-potsdam.de Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : CDDIS Secondary Data Center : IGN URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions AOAD/M_T ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0380 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 -->