AUBU00FRA Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : EOST GNSS team (renag-eost@eost.unistra.fr) Date Prepared : 2024-08-29 Report Type : UPDATE If Update: Previous Site Log : aubu00fra_20240827.log Modified/Added Sections : 12 1. Site Identification of the GNSS Monument Site Name : Aubure Four Character ID : AUBU Monument Inscription : NONE IERS DOMES Number : 19977M001 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : 2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 1.20 m Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 2008-07-05 Geologic Characteristic : BEDROCK Bedrock Type : IGNEOUS Bedrock Condition : WEATHERED Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Aubure State or Province : Haut Rhin Country : France Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4224986.634 Y coordinate (m) : 533493.569 Z coordinate (m) : 4733835.556 Latitude (N is +) : +481300.67 Longitude (E is +) : +0071148.16 Elevation (m,ellips.) : 1151.8 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4619207665 Firmware Version : 1.1-3 Elevation Cutoff Setting : 0 deg Date Installed : 2008-07-05 Date Removed : 2015-08-07T09:19Z Temperature Stabiliz. : none Additional Information : Any T00 or RINEX files related to this site : before 2008 07 05 (DOY 187) correspond to : test measurements made on other monument markers 3.2 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4619207665 Firmware Version : 1.3-2 Elevation Cutoff Setting : 0 deg Date Installed : 2015-08-07T09:22Z Date Removed : 2016-09-28T13:30Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.3 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL Serial Number : 5607R50113 Firmware Version : 5.14 Elevation Cutoff Setting : 0 deg Date Installed : 2016-09-28T13:42Z Date Removed : 2021-09-29T09:19Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.4 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL Serial Number : 5607R50113 Firmware Version : 5.37 Elevation Cutoff Setting : 0 deg Date Installed : 2021-09-29T09:19Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM41249.00 NONE Serial Number : 60135222 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : 25 m Date Installed : 2008-07-05 Date Removed : 2016-09-28T13:30Z Additional Information : Complete part number is 41249.00 DC 4609, : original cable length is 30 m, : reduced to about 25 m. 4.2 Antenna Type : TRM57971.00 NONE Serial Number : 1441014789 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : 25 m Date Installed : 2016-09-28T13:42Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Complete part number is 57971.00 DC 5602, : original antenna cable is used, ie not changed. 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2008-07-05/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 60 sec Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2008-07-05/2016-09-28 Notes : horizontal distance between antenna and sensor : is about 3 m 8.1.2 Humidity Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 300 sec Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2016-09-29/CCYY-MM-DD Notes : horizontal distance between antenna and sensor : is about 3 m, only the sampling rate has changed 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 60 sec Accuracy : (hPa) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2008-07-05/2016-09-28 Notes : (multiple lines) 8.2.2 Pressure Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 300 sec Accuracy : (hPa) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2016-09-29/CCYY-MM-DD Notes : Only sampling rate has changed. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 60 sec Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2008-07-05/2016-09-28 Notes : (multiple lines) 8.3.2 Temp. Sensor Model : PTU300 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 300 sec Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2016-09-29/CCYY-MM-DD Notes : Only the sampling rate has changed. 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : Pluviometer 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : TV/CELL PHONE ANTENNA Observed Degradations : SN RATIO Effective Dates : 2008-07-08/CCYY-MM-DD Additional Information : (multiple lines) 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Ecole et Observatoire des Sciences de la Terre Preferred Abbreviation : EOST Mailing Address : rue René Descartes 5 : F-67084 Strasbourg Cedex : France Primary Contact Contact Name : EOST GNSS team Telephone (primary) : Telephone (secondary) : Fax : E-mail : renag-eost@eost.unistra.fr Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Epos-France : RENAG : CNRS Preferred Abbreviation : Epos-Fr Mailing Address : rue Michel-Ange 3 : 75796 Paris Cedex 16 : France Primary Contact Contact Name : RENAG GNSS direction and data center Telephone (primary) : Telephone (secondary) : Fax : E-mail : renag-ops@groupes.renater.fr Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : Additional contact: patrice.ulrich@unistra.fr 13. More Information Primary Data Center : RENAG (ftp://renag.unice.fr) Secondary Data Center : IGN ( ftp://rgpdata.ign.fr : andftp://rgpdata.ensg.ign.fr) URL for More Information : http://webrenag.unice.fr/fiches.php Hardcopy on File Site Map : Y Site Diagram : Y Horizon Mask : Y Monument Description : Y Site Pictures : Y Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM57971.00 / --------------------------------------------- \ + + \ --------------------------------------------- / \ / \ / \-----x-----/ <-- 0.0000 BAM=ARP RXC=NRP <-- 0.3396 --> Notches