BRMG00DEU Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : GREF Operator (operator.gref@bkg.bund.de) Date Prepared : 2024-09-03 Report Type : UPDATE If Update: Previous Site Log : brmg00deu_20240215.log Modified/Added Sections : 3.6, 3.7, 8.1.1, 8.2.1, 8.3.1 1. Site Identification of the GNSS Monument Site Name : Bremgarten Four Character ID : BRMG Monument Inscription : IERS DOMES Number : 10918M001 CDP Number : (A4) Monument Description : Steelpipe with heat protection Height of the Monument : 1.8 m Monument Foundation : 2020 Foundation Depth : 7 m Marker Description : SURVEY MARKER BOLT ON THE PILLAR Date Installed : 2020-03-05 Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : Survey Marker Bolt on a pillar. : Antenna mounted with a special screw : adapter on a rivet thread of a circular : tube of steel filled with concrete, : 8.8 m length, : placed on the ground at airport of Bremgarten. 2. Site Location Information City or Town : Bremgarten State or Province : Baden Wuerttemberg Country : Germany Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4245557.100 Y coordinate (m) : 568958.100 Z coordinate (m) : 4710200.000 Latitude (N is +) : +475427.86 Longitude (E is +) : +0073758.36 Elevation (m,ellips.) : 261.6 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 3.7.9 DEC,30,2019 Elevation Cutoff Setting : 0 deg Date Installed : 2020-04-08T10:00Z Date Removed : 2020-11-05T08:45Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.2 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 3.7.10 Oct,22,2020 Elevation Cutoff Setting : 0 deg Date Installed : 2020-11-05T08:45Z Date Removed : 2021-08-31T07:55Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.3 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 4.1.03-210713 Elevation Cutoff Setting : 0 deg Date Installed : 2021-08-31T07:55Z Date Removed : 2022-03-03T06:16Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.4 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 4.1.04-211206 Elevation Cutoff Setting : 0 deg Date Installed : 2022-03-03T06:16Z Date Removed : 2023-02-08T09:27Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.5 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 4.1.06-221128 Elevation Cutoff Setting : 0 deg Date Installed : 2023-02-08T09:27Z Date Removed : 2024-02-15T08:15Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.6 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02887 Firmware Version : 4.3.00-231129 Elevation Cutoff Setting : 0 deg Date Installed : 2024-02-15T08:15Z Date Removed : 2024-09-03T13:00Z Temperature Stabiliz. : none Additional Information : Bord ID: 10775LR9W4R3L0QDSPVJA2QGHS 3.7 Receiver Type : JAVAD TRE_3S DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 04934 Firmware Version : 4.3.00-231129 Elevation Cutoff Setting : 0 deg Date Installed : 2024-09-03T13:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Bord ID: S34A9C790A834550FBD01823BA 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAR25.R4 LEIT Serial Number : 726856 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0450 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : ECOFLEX10+ Antenna Cable Length : 20 m Date Installed : 2020-04-08T10:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Antenna individual calibrated absolutely by : : GEO++ - ROBOT 2017-10-24 : : UNI BONN - CHAMBER 2018-01-31 : : Senatsverwaltung Berlin - ROBOT 2019-12-17 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2020-03-05/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GNSS BRMG01DEU Status : PERMANENT Effective Dates : 2020-04-08/CCYY-MM-DD Notes : Secondary Receiver at the same antenna. : More information and data available on : request. 7.2 Instrumentation Type : CORNER REFLECTOR Status : PERMANENT Effective Dates : 2020-09-24/CCYY-MM-DD Notes : Pair of 1 m^3 passive retroreflectors 30 m away : from BRMG connected via regular terrestrial : survey for InSAR. Mounted on 5 m^2 concrete : foundation oriented to ascending and : descending sun synchronous orbits. : More information and data available on : request. 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : P3240139 Data Sampling Interval : 10 sec Accuracy (% rel h) : 3 % rel h Aspiration : NATURAL Height Diff to Ant : -0.5 m Calibration date : 2018-08-13 Effective Dates : 2020-04-09/CCYY-MM-DD Notes : Vaisala WXT530 (heated) SN: P3710988 : Humidity Sensor is 0.5 m under the antenna : capacitive thin film polymer HUMICAP 180 sensor 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : P3240139 Data Sampling Interval : 10 sec Accuracy : 1 hPa Height Diff to Ant : -0.5 m Calibration date : 2018-08-13 Effective Dates : 2020-04-09/CCYY-MM-DD Notes : Vaisala WXT530 (heated) SN: P3710988 : Pressure Sensor is 0.5 m under the antenna : capacitive silicon BAROCAP sensor 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : P3240139 Data Sampling Interval : 10 sec Accuracy : 0.3 deg C Aspiration : NATURAL Height Diff to Ant : -0.5 m Calibration date : 2018-08-13 Effective Dates : 2020-04-09/CCYY-MM-DD Notes : Vaisala WXT530 (heated) SN: P3710988 : Temperature Sensor is 1 m under the antenna : capacitive ceramic THERMOCAP sensor 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : Wind Azimut : Wind Sensor Model WXT530 (heated) : Manufacturer Vaisala : Serial Number P3710988 : Data Sampling Interval 10 sec : Accuracy 3 deg : Height Diff to Ant -0.5 m : Test date 2018-08-13 : Effective Dates 2020-04-09/CCYY-MM-DD : Notes Wind Sensor is 0.5 m under the antenna : Notes ultrasonic WINDCAP sensor 8.5.2 Other Instrumentation : Wind Speed : Wind Sensor Model WXT530 (heated) : Manufacturer Vaisala : Serial Number P3710988 : Data Sampling Interval 10 sec : Accuracy : measurement values 0..35 m/s 0.3 m/s or 3% : measurement values 36..60 m/s 5% : Height Diff to Ant -0.5 m : Test date 2018-08-13 : Effective Dates 2020-04-09/CCYY-MM-DD : Notes Wind Sensor is 0.5 m under the antenna : Notes ultrasonic WINDCAP sensor 8.5.3 Other Instrumentation : Rain Increment : Rain Sensor Model WXT530 (heated) : Manufacturer Vaisala : Serial Number P3710988 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant -0.5 m : Test date 2018-08-13 : Effective Dates 2020-04-09/CCYY-MM-DD : Notes Rain Sensor is 0.5 m under the antenna : Notes piezoelectrical RAINCAP sensor 8.5.4 Other Instrumentation : Hail Indicator : Hail Sensor Model WXT530 (heated) : Manufacturer Vaisala : Serial Number P3710988 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant -0.5 m : Test date 2018-08-13 : Effective Dates 2020-04-09/CCYY-MM-DD : Notes Hail Sensor is 0.5 m under the antenna : Notes piezoelectrical RAINCAP sensor 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie : Department of Geodaesie Preferred Abbreviation : BKG Mailing Address : Richard-Strauss-Allee 11 : D-60598 Frankfurt a.M. : Germany Primary Contact Contact Name : GREF Operator Telephone (primary) : +49 341 5634410 Telephone (secondary) : +49 341 5634432 Fax : +49 341 5634415 E-mail : operator.gref@bkg.bund.de Secondary Contact Contact Name : BKG GNSS Data Center Telephone (primary) : +49 69 6333274 Telephone (secondary) : +49 69 63331 Fax : +49 69 6333425 E-mail : bkg-gdc@bkg.bund.de Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKG Secondary Data Center : BEV URL for More Information : https://gref.bkg.bund.de Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : Y Additional Information : (multiple lines) Antenna Graphics with Dimensions LEIAR25.R4 +-------+ <-- 0.1995 / \ +---+-------------+---+ <-- 0.1606 TCR | | |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3802 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole BOP: Bottom of Pole All dimensions are in meters.