PFAN00AUT Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : apos.admin@bev.gv.at Date Prepared : 2023-04-27 Report Type : UPDATE If Update: Previous Site Log : pfan00aut_20230421.log Modified/Added Sections : 11, 12 1. Site Identification of the GNSS Monument Site Name : Pfaender/Moos/Bregenz Four Character ID : PFAN Monument Inscription : T0039-082L2 IERS DOMES Number : 11005S002 CDP Number : none Monument Description : PILLAR Height of the Monument : 2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 2 m Marker Description : MANTLED STEEL ROD Date Installed : 1997-04-10T00:00Z Geologic Characteristic : BEDROCK Bedrock Type : SEDIMENTARY Bedrock Condition : FRESH Fracture Spacing : 1-10 cm Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Bregenz State or Province : Vorarlberg Country : Austria Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4253560.000 Y coordinate (m) : 733545.000 Z coordinate (m) : 4681453.000 Latitude (N is +) : +473055.18 Longitude (E is +) : +0094704.79 Elevation (m,ellips.) : 1090.3 Additional Information : DATUM = ETRF89 Austria 2002 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 9384 Firmware Version : 00712|00304 Elevation Cutoff Setting : 7 deg Date Installed : 1997-04-10T00:00Z Date Removed : 1999-07-27T08:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 9384 Firmware Version : 7.29 Elevation Cutoff Setting : 7 deg Date Installed : 1999-07-27T08:00Z Date Removed : 2000-11-09T08:00Z Temperature Stabiliz. : none Additional Information : new firmware installed 3.3 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 8872 Firmware Version : 7.29 Elevation Cutoff Setting : 7 deg Date Installed : 2000-11-09T08:00Z Date Removed : 2004-03-19T11:00Z Temperature Stabiliz. : none Additional Information : receiver change 3.4 Receiver Type : ASHTECH UZ-12 Satellite System : GPS Serial Number : 11113 Firmware Version : CJ100 Elevation Cutoff Setting : 0 deg Date Installed : 2004-03-19T12:00Z Date Removed : 2005-11-29T16:00Z Temperature Stabiliz. : none Additional Information : receiver change 3.5 Receiver Type : ASHTECH UZ-12 Satellite System : GPS Serial Number : 10410 Firmware Version : CJ100 Elevation Cutoff Setting : 0 deg Date Installed : 2005-11-29T16:00Z Date Removed : 2007-11-29T12:00Z Temperature Stabiliz. : none Additional Information : station replaced by new station PFA2 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM22020.00+GP PFAN Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : PFAN Radome Serial Number : OEAW-02/2007 Antenna Cable Type : RG213 Antenna Cable Length : 10 m Date Installed : 1997-04-10T00:00Z Date Removed : 1999-10-28T06:38Z Additional Information : Antenna change caused heightjump 4.2 Antenna Type : TRM29659.00 PFAN Serial Number : 94221 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : PFAN Radome Serial Number : OEAW-02/2007 Antenna Cable Type : RG213 Antenna Cable Length : 10 m Date Installed : 1999-10-28T06:39Z Date Removed : 2000-11-09T08:00Z Additional Information : (multiple lines) 4.3 Antenna Type : TRM29659.00 PFAN Serial Number : 173810 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : PFAN Radome Serial Number : OEAW-02/2007 Antenna Cable Type : RG213 Antenna Cable Length : 10 m Date Installed : 2000-11-09T08:00Z Date Removed : 2004-03-19T11:00Z Additional Information : antenna change 4.4 Antenna Type : ASH701945C_M PFAN Serial Number : 11703 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : PFAN Radome Serial Number : OEAW-02/2007 Antenna Cable Type : RG213 Antenna Cable Length : 10 m Date Installed : 2004-03-19T12:00Z Date Removed : 2007-11-29T12:00Z Additional Information : station replaced by new station PFA2 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : PFA2 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : 11005M003 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -0.114 m dy (m) : -0.020 m dz (m) : -0.128 m Accuracy (mm) : 1 mm Survey method : NIVELLEMENT Date Measured : 2007-11-29T12:00Z Additional Information : dE=0.000, dN=0.000, dH=-0.173 5.2 Tied Marker Name : PFAN (EUREF 060) Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : 11005M002 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -3.225 m dy (m) : 22.381 m dz (m) : 0.678 m Accuracy (mm) : 2 mm Survey method : TRIANGULATION+DISTANCE+GPS Date Measured : 1999-11-15T10:00Z Additional Information : Central marker (Swiss bolt on pillar) 5.3 Tied Marker Name : KT-bolt Austria Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -3.190 m dy (m) : 22.179 m dz (m) : 0.665 m Accuracy (mm) : 2 mm Survey method : TRIANGULATION+DISTANCE+GPS Date Measured : 1999-11-15T10:00Z Additional Information : Second marker on pillar 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 1996-11-01/2007-11-29 Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Testo 454 Manufacturer : Testoterm Serial Number : Data Sampling Interval : 60 sec Accuracy (% rel h) : 2 % rel h Aspiration : UNASPIRATED Height Diff to Ant : 2 m Calibration date : (CCYY-MM-DD) Effective Dates : 1999-10-28/CCYY-MM-DD Notes : 10 minutes samples distributed 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Kroneis 315 K Manufacturer : Kroneis Serial Number : Data Sampling Interval : 60 sec Accuracy : 0.2 hPa Height Diff to Ant : 2 m Calibration date : (CCYY-MM-DD) Effective Dates : 1999-10-28/CCYY-MM-DD Notes : 10 minutes samples distributed 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Testo 454 Manufacturer : Testoterm Serial Number : Data Sampling Interval : 60 sec Accuracy : 0.2 deg C Aspiration : UNASPIRATED Height Diff to Ant : 2 m Calibration date : (CCYY-MM-DD) Effective Dates : 1999-10-28/CCYY-MM-DD Notes : 10 minutes samples distributed 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : CELL PHONE ANTENNA Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Additional Information : still waiting for installment 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Federal Office of Metrology and Surveying : Austria : Dept. Control Survey Preferred Abbreviation : BEV Mailing Address : Schiffamtsgasse 1-3 : A-1020 Wien : Austria Primary Contact Contact Name : APOS - Austrian Positioning Service Telephone (primary) : +43 676 82101111 Telephone (secondary) : Fax : E-mail : apos.admin@bev.gv.at Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : OLG Secondary Data Center : BKGE URL for More Information : http://www.bev.gv.at/ Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : 0 Monument Description : see below Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions ASH701945C_M +-------+ / + \ | + | +-----------------+-------------+------------------+ <-- 0.1006 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0376 +-------------------+-------------+--------------------+ <-- 0.0346 BCR | | | | +------x------+ <-- 0.0 BPA=ARP <-- 0.3794 --> Monument description _______ / \ / _ \ | ___/ \___ |-- GRP radome | |_________| | <--- 0.000 BPA=ARP |_____ | _____| <--- -0.168 RADOM GP || | || || | || || | ||-- galvanized || | || steel || | || || | || // | \\ || |--- || -- protected iron rod || | || || | || ------------------------- <--- -1.650 BOTTOM PLATE |////// concrete \\\\\\| |///////////\\\\\\\\\\\\\| / \