TUC200GRC Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Stelios P. Mertikas Date Prepared : 2020-07-17 Report Type : UPDATE If Update: Previous Site Log : tuc200grc_20190329.log Modified/Added Sections : 3.8, 3.9, 13 1. Site Identification of the GNSS Monument Site Name : Technical University of Crete Four Character ID : TUC2 Monument Inscription : IERS DOMES Number : 12617M003 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : 1.20 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 0.70 m Marker Description : CENTER OF ANTENNA MOUNTING PLATE Date Installed : 2004-06-16T00:00Z Geologic Characteristic : BEDROCK Bedrock Type : SEDIMENTARY Bedrock Condition : FRESH Fracture Spacing : 1-10 cm Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : TUC2 site is installed and maintained by : the Geodesy and Geomatics Engineering Lab : of the Mineral Resources Engineering Dept : of the Technical University of Crete, : Chania, Greece. 2. Site Location Information City or Town : Chania State or Province : Crete Country : Greece Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4744543.851 Y coordinate (m) : 2119411.870 Z coordinate (m) : 3686258.942 Latitude (N is +) : +353159.49 Longitude (E is +) : +0240414.01 Elevation (m,ellips.) : 161.0 Additional Information : TUC2 site is located in the Technical : University of Crete Campus, Chania, Greece. 3. GNSS Receiver Information 3.1 Receiver Type : LEICA RS500 Satellite System : GPS Serial Number : 0080199 Firmware Version : 4.2 Elevation Cutoff Setting : 0 deg Date Installed : 2004-06-20T00:00Z Date Removed : 2008-12-10T00:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS Serial Number : 352838 Firmware Version : 5.62/3.014 Elevation Cutoff Setting : 0 deg Date Installed : 2008-12-10T00:00Z Date Removed : 2010-06-14T06:00Z Temperature Stabiliz. : none Additional Information : GRX1200GGPRO Receiver is capable of recording : Glonass data. However this is not done because : the Glonass option is locked on the receiver. : The local leica vendor was not providing the : option free of charge and the given budget at : the time was not enough to unlock this option. : On 17 March 2010 (DOY 2010/076, 13:20 UTC) the : 'Code smoothing' tracking parameter was changed : from 'Smoothed' to 'Not smoothed'. 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS Serial Number : 352838 Firmware Version : 8.00/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2010-06-14T07:00Z Date Removed : 2010-07-15T06:30Z Temperature Stabiliz. : none Additional Information : GRX1200GGPRO Receiver is capable of recording : Glonass data. However this is not done because : the Glonass option is locked on the receiver. : The local leica vendor was not providing the : option free of charge and the given budget at : the time was not enough to unlock this option. : On 17 March 2010 (DOY 2010/076, 13:20 UTC) the : 'Code smoothing' tracking parameter was changed : from 'Smoothed' to 'Not smoothed'. 3.4 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495906 Firmware Version : 8.00/4.004 Elevation Cutoff Setting : 0 deg Date Installed : 2010-07-15T09:10Z Date Removed : 2011-03-11T11:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.5 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495906 Firmware Version : 8.10/4.004 Elevation Cutoff Setting : 0 deg Date Installed : 2011-03-11T11:00Z Date Removed : 2014-05-05T08:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.6 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495906 Firmware Version : 8.71/6.112 Elevation Cutoff Setting : 0 deg Date Installed : 2014-05-05T08:00Z Date Removed : 2015-01-21T08:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.7 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495906 Firmware Version : 9.20/6.404 Elevation Cutoff Setting : 0 deg Date Installed : 2015-01-21T08:00Z Date Removed : 2019-03-29T07:00Z Temperature Stabiliz. : none Additional Information : (multiple lines) 3.8 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495906 Firmware Version : 9.20/6.405 Elevation Cutoff Setting : 0 deg Date Installed : 2019-03-29T07:00Z Date Removed : 2020-07-11T23:59Z Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.9 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO+GAL+BDS Serial Number : 495906 Firmware Version : 9.20/6.405 Elevation Cutoff Setting : 0 deg Date Installed : 2020-07-12T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAT504 NONE Serial Number : 212 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0337 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Leica supplied Antenna Cable Length : 30 m Date Installed : 2004-06-20T00:00Z Date Removed : 2004-10-14T10:00Z Additional Information : Removed due to poor quality of data : (Satellite visibility problems in North : sector) 4.2 Antenna Type : LEIAT504 NONE Serial Number : 424 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0343 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Leica supplied Antenna Cable Length : 30 m Date Installed : 2004-10-14T10:00Z Date Removed : 2010-07-15T06:30Z Additional Information : (multiple lines) 4.3 Antenna Type : LEIAR25.R3 NONE Serial Number : 10020008 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0393 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Leica supplied Antenna Cable Length : 30 m Date Installed : 2010-07-15T09:10Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : R00 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -0.200 m dy (m) : 0.090 m dz (m) : -1.003 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.2 Tied Marker Name : R01 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -8.300 m dy (m) : 6.820 m dz (m) : -0.704 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.3 Tied Marker Name : R02 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -0.650 m dy (m) : 9.070 m dz (m) : -0.864 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.4 Tied Marker Name : R03 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 10.580 m dy (m) : -4.750 m dz (m) : -0.992 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.5 Tied Marker Name : R04 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 5.600 m dy (m) : -3.060 m dz (m) : -0.949 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.6 Tied Marker Name : R05 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -0.270 m dy (m) : -17.120 m dz (m) : -0.541 m Accuracy (mm) : 0.5 mm Survey method : TRILATERATION/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.7 Tied Marker Name : SLR0 Tied Marker Usage : SLR, LOCAL CONTROL, GPS Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -1.090 m dy (m) : -16.450 m dz (m) : -0.544 m Accuracy (mm) : 0.5 mm Survey method : GPS CAMPAIGN/TRIANGULATION/LEVELLING Date Measured : 2004-06-18T00:00Z Additional Information : (multiple lines) 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2004-06-16/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP45A-P Humidity and Temperature probe Manufacturer : Vaisala Oyj, Finland Serial Number : X1540004 Data Sampling Interval : 180 sec Accuracy (% rel h) : 1 % rel h Aspiration : NATURAL Height Diff to Ant : 16 m Calibration date : 2003-05-27 Effective Dates : 2003-09-01/2006-12-12 Notes : (multiple lines) 8.1.2 Humidity Sensor Model : PAROSCIENTIFIC MET3 Manufacturer : PAROSCIENTIFIC Serial Number : X1550001 Data Sampling Interval : 60 sec Accuracy (% rel h) : 1 % rel h Aspiration : NATURAL Height Diff to Ant : 2 m Calibration date : 2006-10-10 Effective Dates : 2006-12-12/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU200 Class A PTU transmitter Manufacturer : Vaisala Oyj, Finland Serial Number : X1540004 Data Sampling Interval : 180 sec Accuracy : 0.07 hPa Height Diff to Ant : 13 m Calibration date : 2002-04-11 Effective Dates : 2003-09-01/2006-12-12 Notes : (multiple lines) 8.2.2 Pressure Sensor Model : PAROSCIENTIFIC MET3 Manufacturer : PAROSCIENTIFIC Serial Number : X1550001 Data Sampling Interval : 60 sec Accuracy : 0.07 hPa Height Diff to Ant : 2 m Calibration date : 2006-10-10 Effective Dates : 2006-12-12/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMP45A-P Humidity and Temperature probe Manufacturer : Vaisala Oyj, Finland Serial Number : X1540004 Data Sampling Interval : 180 sec Accuracy : 0.15 deg C Aspiration : NATURAL Height Diff to Ant : 16 m Calibration date : 2003-05-27 Effective Dates : 2003-09-01/2006-12-12 Notes : (multiple lines) 8.3.2 Temp. Sensor Model : PAROSCIENTIFIC MET3 Manufacturer : PAROSCIENTIFIC Serial Number : X1550001 Data Sampling Interval : 60 sec Accuracy : 0.15 deg C Aspiration : NATURAL Height Diff to Ant : 2 m Calibration date : 2006-10-10 Effective Dates : 2006-12-12/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Technical University of Crete : Mineral Resources Engineering Department : Geodesy and Geomatics Laboratory Preferred Abbreviation : TUC Mailing Address : University Campus : 73100 Chania : Greece Primary Contact Contact Name : Stelios P. Mertikas Telephone (primary) : +30 2821 037629 Telephone (secondary) : Fax : +30 2821 037872 E-mail : mertikas@mred.tuc.gr Secondary Contact Contact Name : Xenophon A. Frantzis Telephone (primary) : +30 2821 037687 Telephone (secondary) : Fax : +30 2821 037872 E-mail : xfratzis@mred.tuc.gr Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BEV Secondary Data Center : BKG URL for More Information : http://www.geomatlab.tuc.gr Hardcopy on File Site Map : Y Site Diagram : Y Horizon Mask : Y Monument Description : Y Site Pictures : Y Additional Information : (multiple lines) Antenna Graphics with Dimensions LEIAR25 +-------+ <-- 0.1995 / \ +- -+ |---+-------------+---| <-- 0.1456 TCR |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP