UPOL00CZE Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : GOP operation center (gop_oc@pecny.cz) Date Prepared : 2024-08-29 Report Type : UPDATE If Update: Previous Site Log : upol00cze_20200716.log Modified/Added Sections : 11 1. Site Identification of the GNSS Monument Site Name : UP Olomouc Four Character ID : UPOL Monument Inscription : IERS DOMES Number : 11591M001 CDP Number : none Monument Description : STEEL ROD ON THE ROOF OF BUILDING Height of the Monument : 1.6 m Monument Foundation : WALL ON THE ROOF Foundation Depth : 5 m Marker Description : SCREW ON THE STEEL ROD Date Installed : 2015-10-01 Geologic Characteristic : ?SAND Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : Foundation Depht is underground part of : building. Height of building (between ground : level and roof) is 32.5 m. Point is 34.1 m : above ground. 2. Site Location Information City or Town : Olomouc State or Province : Moravia Country : Czechia Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3955930.543 Y coordinate (m) : 1229640.594 Z coordinate (m) : 4833786.022 Latitude (N is +) : +493534.59 Longitude (E is +) : +0171601.41 Elevation (m,ellips.) : 291.8 Additional Information : Aproximate coordinates from RINEX header 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS+SBAS Serial Number : 50077 Firmware Version : 4.85 Elevation Cutoff Setting : 0 deg Date Installed : 2016-01-07T14:49Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Full serial number is 5450K50077 : Date Installed = date of first transferred data 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM59900.00 SCIS Serial Number : 5319361131 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0015 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 80 deg Antenna Radome Type : SCIS Radome Serial Number : 1749 Antenna Cable Type : Trimble TIMA40G-100 Antenna Cable Length : 30 m Date Installed : 2016-01-07T14:49Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Phase centers absolute calibrated at Geo++ on : April 24, 2015 : Date Installed = date of first transferred data 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2016-01-07/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : T3111 Manufacturer : COMET SYSTEM, CZ Serial Number : 15961287 Data Sampling Interval : 60 sec Accuracy (% rel h) : 3 % rel h Aspiration : NATURAL Height Diff to Ant : -0.53 m Calibration date : 2017-08-03 Effective Dates : 2015-10-15/CCYY-MM-DD Notes : the sensor is 0.53 m below monument marker : (reference point UPOL 11591M001) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : T2114 Manufacturer : COMET SYSTEM, CZ Serial Number : 15962382 Data Sampling Interval : 60 sec Accuracy : 0.5 hPa Height Diff to Ant : -1.15 m Calibration date : 2017-08-03 Effective Dates : 2015-10-15/CCYY-MM-DD Notes : the sensor is 1.15 m below monument marker : (reference point UPOL 11591M001) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : T3111 Manufacturer : COMET SYSTEM, CZ Serial Number : 15961287 Data Sampling Interval : 60 sec Accuracy : 0.5 deg C Aspiration : NATURAL Height Diff to Ant : -0.53 m Calibration date : 2017-08-03 Effective Dates : 2015-10-15/CCYY-MM-DD Notes : the sensor is 0.53 m below monument marker : (reference point UPOL 11591M001) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : wind speed sensor model: tm J. Tlustak type: : 1Wt420 SN: 1453 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : University Palackeho in Olomouc : Faculty of Science : Department of Geoinformatics Preferred Abbreviation : UP OLOMOUC Mailing Address : 17. listopadu 50 : CZ-77146 Olomouc : Czechia Primary Contact Contact Name : GOP operation center Telephone (primary) : Telephone (secondary) : Fax : E-mail : gop_oc@pecny.cz Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Research Institute of Geodesy, Topography and : Cartography : Geodetic Observatory Pecny Preferred Abbreviation : RIGTC GOP Mailing Address : Pecny 244 : CZ-25165 Ondrejov : Czechia Primary Contact Contact Name : GOP operation center Telephone (primary) : Telephone (secondary) : Fax : E-mail : gop_oc@pecny.cz Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : VESOG operational center Secondary Data Center : CZEPOS network center URL for More Information : http://oko.pecny.cz/vesog/ Hardcopy on File Site Map : on the web page Site Diagram : no Horizon Mask : no Monument Description : no Site Pictures : on the web page Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM59900.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 --> Heights above monument marker ----- / \ | | +-------------------------------------------------+ <-- 0.1035 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0396 +-------------------+-------------+-------------------+ <-- 0.0365 BCR | | =| | +------x------+ <-- 0.0015 BPA=ARP screew +--x--+ <-- 0.0000 ref.point +-+-----+-+ | | | | | | | | | | | R O D | | | | | | | | | | | | |