VARD00NOR Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : asmund.skjaeveland@kartverket.no Date Prepared : 2024-10-18 Report Type : UPDATE If Update: Previous Site Log : vard00nor_20181203.log Modified/Added Sections : 11 1. Site Identification of the GNSS Monument Site Name : Vardoe Four Character ID : VARD Monument Inscription : STATENS KARTVERK IERS DOMES Number : 10322M002 CDP Number : (A4) Monument Description : (PILLAR/BRASS PLATE/STEEL MAST/etc) Height of the Monument : (m) Monument Foundation : (STEEL RODS, CONCRETE BLOCK, ROOF, etc) Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 1995-07-17 Geologic Characteristic : BEDROCK Bedrock Type : METAMORPHIC Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : Sedimentary bedrock. : : VARD : Date removed: 2000-04-17T12:00Z : Site superseded by VARS : 2. Site Location Information City or Town : Vardoe State or Province : Finnmark Country : Norway Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 1844607.623 Y coordinate (m) : 1109719.107 Z coordinate (m) : 5983936.007 Latitude (N is +) : +702010.93 Longitude (E is +) : +0310152.28 Elevation (m,ellips.) : 174.8 Additional Information : Local name is : DOMEN 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 3511A10119 Firmware Version : 7.03 Elevation Cutoff Setting : 10 deg Date Installed : 1995-07-17 Date Removed : 1998-06-16T18:00Z Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 3511A10119 Firmware Version : 7.28 Elevation Cutoff Setting : 10 deg Date Installed : 1998-06-16T19:25Z Date Removed : 2000-04-17T12:00Z Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM23903.00 NONE Serial Number : Unknown Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 5.0330 Marker->ARP North Ecc(m) : 0.0140 Marker->ARP East Ecc(m) : 0.0280 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1995-07-17 Date Removed : 1997-10-16T10:40Z Additional Information : The antenna type TR GEOD L1/L2 GP is not : the right type : 45 degree angel roof made of glassfiber 4.2 Antenna Type : TRM29659.00 DOME Serial Number : 0220098649 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 5.0330 Marker->ARP North Ecc(m) : 0.0140 Marker->ARP East Ecc(m) : 0.0280 Alignment from True N : 0 deg Antenna Radome Type : DOME Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1997-10-16T11:13Z Date Removed : 1998-06-16T18:00Z Additional Information : Degree Offset from North : 180 ? : Antenna contact pointed towards South : 45 degree angel roof made of glassfiber 4.3 Antenna Type : TRM29659.00 SCIS Serial Number : 0220098649 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 5.5120 Marker->ARP North Ecc(m) : 0.0060 Marker->ARP East Ecc(m) : 0.0170 Alignment from True N : 0 deg Antenna Radome Type : SCIS Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1998-06-16T19:25Z Date Removed : 2009-05-05T11:05Z Additional Information : Degree Offset from North : 0? : Antenna contact points towards North : SCIS Installed 20-DEC-1999 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : ARP of TRIMBLE permanent L1/L2 Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 1.427 m dy (m) : 0.891 m dz (m) : 4.744 m Accuracy (mm) : 1 mm Survey method : UNKNOWN Date Measured : 1995-07-17 Additional Information : Differential coordinates from the GPS : monument (Marker with Domes No.) to the ARP. : The components are parallel to the XYZ-axes : of the global geocentric reference system : ITRF (WGS-84). Differential Components from : GPS Mark to Site Reference (ITRS) : (ARP minus top bolt) 5.2 Tied Marker Name : ARP of TRM29659.00 Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 1.427 m dy (m) : 0.891 m dz (m) : 4.744 m Accuracy (mm) : 1 mm Survey method : UNKNOWN Date Measured : 1995-07-17 Additional Information : Differential coordinates from the GPS : monument (Marker with Domes No.) to the ARP. : The components are parallel to the XYZ-axes : of the global geocentric reference system : ITRF (WGS-84). Differential Components from : GPS Mark to Site Reference (ITRS) : (ARP minus top bolt) 5.3 Tied Marker Name : ARP of TRM29659.00 Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 1.576 m dy (m) : 0.967 m dz (m) : 5.192 m Accuracy (mm) : 2 mm Survey method : UNKNOWN Date Measured : 1998-06-16 Additional Information : Differential coordinates from the GPS : monument (Marker with Domes No.) to the ARP. : The components are parallel to the XYZ-axes : of the global geocentric reference system : ITRF (WGS-84). Differential Components from : GPS Mark to Site Reference (ITRS) : (ARP minus top bolt) 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 1995-07-17/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Norwegian Mapping Authority : Geodetic Institute Preferred Abbreviation : NMA Mailing Address : Kartverksveien 21 / P.O.Box 600 Sentrum : N-3507 Honefoss : Norway Primary Contact Contact Name : SATREF Control Centre Telephone (primary) : Telephone (secondary) : Fax : E-mail : satref@kartverket.no Secondary Contact Contact Name : Dr. Aasmund Steen Skjaeveland Telephone (primary) : +47 32 11 84 52 Telephone (secondary) : Fax : +47 32 11 81 01 E-mail : asmund.skjaeveland@kartverket.no Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKG Secondary Data Center : URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM29659.00 Trimble L1/L2 Dorne Margolin element with chokerings Model 29659.00 +-------+ / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +--------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0380 +-------------------+-------------+--------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.0 BPA=ARP <-- 0.3810 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center